- Scrubbers for Wood-fired Ovens
- Scrubbers for Electric Ovens
- Scrubbers for Charcoal Grills
- Stainless Steel Exhaust Fans
ETC Group S.r.l. Sole Shareholder
Industrial area Pirano, Tavullia
Str. Delle Campagne, 10
61010 Tavullia PU - ITALY
Tel.
+39 0721 1839937
+39 0541 955062
+39 0541 1646150
WhatsApp-web +39 373 7755779
E-Mail DEPARTMENTS
informazioni@etcgroupsrl.biz
commerciale@etcgroupsrl.biz
tecnico@etcgroupsrl.biz
contabilita@etcgroupsrl.biz
VAT and Tax Code: IT 04083110405
Reg. of companies of Pesaro N. REA - PS – 196574
On this page, ETC Group provides designers, installers and technical professionals with three calculation tools for the sizing of extraction and ventilation systems.
The calculators allow you to check the main airflow parameters required during the initial design stages: duct sizing, room air change requirements, and the calculation of airflow rate and total pressure for professional kitchen extraction systems.
Each calculator can be used separately, depending on the parameter to be determined, or the results can be used as a basis for subsequent system checks.
By entering the required geometric and airflow data, the system directly provides the corresponding calculation results.
This calculator allows you to size an extraction duct system according to the airflow rate to be conveyed and to check the main airflow parameters along the ductwork.
By entering the required airflow rate and the characteristics of the duct, you can assess the necessary cross-section or diameter and check the air velocity inside the duct. A correct relationship between airflow rate, duct section and air velocity is necessary to obtain a balanced system and avoid excessive resistance along the airflow path.
The calculation also considers the characteristics of the duct network, including total duct length, dimensions, 90° bends, T-junctions and other components that create resistance to airflow.
Based on the entered data, the system determines the pressure losses generated by both straight duct sections and the fittings installed along the route. This allows you to assess the pressure required to overcome the resistance of the system at the intended airflow rate.
The result provides a technical basis for checking the ductwork sizing and for the subsequent selection of the fan, which must be capable of delivering the required airflow rate at the calculated pressure.
This calculator determines the airflow rate required for a professional extraction hood based on its geometry and on the characteristics of the open area through which the air is drawn.
The calculation uses the hood width and depth, its installation configuration and the height of the extraction opening. These parameters are used to determine the open capture area. By applying the air velocity required by the selected sizing criterion, the necessary airflow rate is then calculated and expressed in m³/h.
The calculation is based on the airflow characteristics of the hood and the open extraction area. The type, number and installed power of the cooking appliances are not used as input parameters for this calculator.
Once the airflow rate has been determined, the characteristics of the duct system can also be entered, including duct dimensions, total length, 90° bends, T-junctions and other components installed along the airflow path.
The system then calculates the pressure losses of the duct network and provides the two main values required for the subsequent sizing of the system: required airflow rate in m³/h and total required system pressure.
The calculation method is developed with reference to the applicable criteria of the UNI EN 16282 series for ventilation systems in professional kitchens.
* This website uses artificial intelligence tools to support text, images, and virtual assistants; all research, projects, solutions, and inventions are the result of human intellectual work. Automated responses are provided for informational purposes only and are non-binding.
| Materiale | Rugosità (mm) |
|---|---|
| Acciaio Inox | 0.001 |
| Plastica (PVC/PP) | 0.01 |
| Acciaio zincato | 0.05 |
| Acciaio zincato (media) | 0.15 |
| Acciaio zincato avvolto | 0.5 |
| Cemento | 1.5 |
Cattura al varco (perimetro aperto × finestra hf) con velocità 0,20–0,50 m/s (opz. 0,60 m/s per braci), perdite condotti (Darcy–Weisbach, K curve/tee, materiale). Calcolo in tempo reale + esportazione PDF.
This calculator determines the amount of air required for room ventilation based on the dimensions of the room and the selected number of air changes per hour.
By entering the length, width and height of the room, the system calculates its total internal volume. This value is then used to determine the required airflow rate according to the selected air change rate.
The calculator can be used as an initial assessment tool for workshops, technical rooms, production areas, professional kitchens and other environments where an air supply or extraction system needs to be sized.
The result is expressed in m³/h and indicates the amount of air that must be moved in order to achieve the selected number of air changes per hour.
The calculated value represents an initial sizing parameter. Final system design must also take into account the actual operating conditions of the room, the sources present and any technical requirements applicable to the specific installation.