Feature Value Filter height 50 cm Extractor height 44 cm Total height 94 cm Filter depth 56 cm Width 62 cm Cold water supply 1/2" Condensate drain to sewer 1" Inlet diameter Ø 150 mm Outlet diameter Ø 140-150 mm Feature | Value |
---|---|
Filter height | 50 cm |
Extractor height | 44 cm |
Total height | 94 cm |
Filter depth | 56 cm |
Width | 62 cm |
Cold water supply | 1/2" |
Condensate drain to sewer | 1" |
Inlet diameter | Ø 150 mm |
Outlet diameter | Ø 140-150 mm |
Technical Data Sheet
User Manual
HIGH TEMPERATURE
ASPIRATORS
+300°
Code. INOX.4.EBR280
ETC Group S.r.l. Sole Shareholder
Industrial area Pirano, Tavullia
Str. Delle Campagne, 10
61010 Tavullia PU - ITALY
Tel.
+39 0721 1839937
+39 0541 955062
+39 0541 1646150
WhatsApp-web +39 373 7755779
E-Mail DEPARTMENTS
informazioni@etcgroupsrl.biz
commerciale@etcgroupsrl.biz
tecnico@etcgroupsrl.biz
contabilita@etcgroupsrl.biz
VAT and Tax Code: IT 04083110405
Reg. of companies of Pesaro N. REA - PS – 196574
- Scrubbers for Wood-fired Ovens
- Scrubbers for Electric Ovens
- Scrubbers for Charcoal Grills
- Stainless Steel Exhaust Fans
Usable on the AH 300 soot reducer
Example of mounting the Filterpac 800 on the chiller
POST-TREATMENT AND REFINEMENT APPARATUSES
If you want to further eliminate odors, or reduce the diffusion of steam coming out of the machine, or
in case of fumes that require additional treatments, a post-treatment apparatus is available that relies on various types of filter panels, applicable at the machine's outlet.
This apparatus, due to its resistance, must necessarily be equipped with a fan and inverter.
The Filterpack is a filter holder box with 4 grooves for the support of the filters themselves. It cannot rest directly
on the machine, as the outlet of the machine itself and the dimensions of the filterpack are not the same.
There is therefore a manifold, which must be fastened to the machine's outlet with a row of screws. A second ring of screws will fasten the manifold to the box. The joints must be siliconed.
Placed on top of the box, a hopper (provided) must be installed, also fastened with screws and siliconed.
Above everything, the fan must be fixed, through its male/female d. 250 joint.
It is recommended to fasten the fan to a fixed support (e.g., with wall brackets of appropriate length) so that it does not
vibrate.
NOTE:
the FILTERPACK device does not guarantee absolute filtration. In some cases, between the scrubber and the filterpack, an
opening is made, equipped with a butterfly valve, to allow fresh air to enter, which contributes to the condensation