Feature    Value
Filter height    50 cm
Extractor height    44 cm
Total height    94 cm
Filter depth    56 cm
Width    62 cm
Cold water supply    1/2"
Condensate drain to sewer    1"
Inlet diameter    Ø 150 mm
Outlet diameter    Ø 140-150 mm
Feature

Value

Filter height50 cm
Extractor height44 cm
Total height94 cm
Filter depth56 cm
Width62 cm
Cold water supply1/2"
Condensate drain to sewer1"
Inlet diameterØ 150 mm
Outlet diameterØ 140-150 mm
patented
filtropianocappe
filterpac500
aspiratori-per-alte-temperature

Technical Data Sheet

User Manual

HIGH TEMPERATURE

ASPIRATORS

+300°

Code. INOX.4.EBR280

scrittanewetctavoladisegno1
cart-icon-png-graphic-cave
tondotavoladisegno1

BECOME

RESELLER

tondotavoladisegno1

facebook
instagram
twitter
linkedin
youtube
phone
whatsapp

ETC Group S.r.l. Sole Shareholder  

Industrial area Pirano, Tavullia

Str. Delle Campagne, 10

61010 Tavullia PU​ - ITALY

For truck route click Here 

 

Tel. 

+39 0721 1839937

+39 0541 955062
+39 0541 1646150​

WhatsApp-web +39 373 7755779

 

E-Mail DEPARTMENTS

informazioni@etcgroupsrl.biz

commerciale@etcgroupsrl.biz

​tecnico@etcgroupsrl.biz

contabilita@etcgroupsrl.biz

 

VAT and Tax Code: IT 04083110405

Reg. of companies of Pesaro  N. REA - PS – 196574

- Soot Scrubbers​

​- Hoods without Chimney

- Water-operated Hood 

​- Scrubbers for Wood-fired Ovens

- Scrubbers for Electric Ovens

- Scrubbers for Charcoal Grills

- Ozone Generators​

- Filters for Kitchen Hoods

- Stainless Steel Exhaust Fans

- Active Carbon Purifiers​

- Electrostatic Filters

- Boxed Exhaust Fans​

- Arturo Purifier

- Water Pump

- Privacy Policy

- Cookie Policy

- Hood with UV-C Lamps

 

scrittanewetctavoladisegno1
1665734
ventilatoriindustriali
56b917_24f385f109d54a5e8849641327b3756b_mv2.jpeg

Fans

industrial centrifugal

cart-icon-png-graphic-cave

for Soot and Grease Eliminators


whatsapp

Contact us

Call Us Now

Centrifugal Industrial Fans: 

The Core of Air Extraction and Filtration Systems

 

Centrifugal industrial fans are the fundamental component of air extraction systems for purification and filtration. These devices generate the necessary airflow to ensure the efficiency of aspiration systems across various industrial applications.

The UNI ISO 13349:2009 standard provides a precise technical definition of centrifugal industrial fans, specifying their characteristics, design criteria, and operational principles.

 

The effectiveness of ventilation is not solely determined by the direction of fan rotation but also by the correct configuration of the discharge outlet, the different construction types, and the motor positioning relative to the fan structure.

From an aerodynamic perspective, air enters the fan impeller in an axial direction and is discharged perpendicularly to the axis of rotation, ensuring efficient air movement and optimal management of flow rates and pressures within the extraction system.

Models

RL Line

Line RM

k1 2000.jpeg

STEEL EXHAUST FANS

Medium - high flow rates and low pressures.

STEEL FAN EXHAUSTERS

Medium flow rates and medium pressures.

Steel Fans Aspirators RM

serierh

Aspiration and transport of clean or slightly dusty air, for the most diverse applications in industrial plant engineering and air conditioning
Working range Medium flow rates and medium pressures. Type Curve Blades, reverse (negative).


Applications
For aspiration and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials. Standard construction executions Standard fluid temperatures -10÷ +60°C.

Type of construction: Fe360 sheet metal fan, Fe360 impeller statically and dynamically balanced.

Operating data: Air intake conditions T=20°C, 0m.a.s.l. and ρ=1.205 kg/m3.

Noise level: Expressed in sound power L w A [dB(A)] measured in free field with ducted fan.

Orientations: No.8 RD (clockwise rotation viewed from drive side) and No.8 LG.

Fan in bolted adjustable version for sizes 250-630, fixed orientation for sizes 710-2000.

Special constructions on request.

RM 250/2

Dimensions

WORK FIELDS

Average flows and average pressures.
TYPE OF IMPELLER

Curved Blade Type, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 0.37 kw, 2850 rpm, noise level 63 db,
Minimum flow rate 470 mc/h with 85 H2o
Maximum flow rate 1370 mc/h with head 44 H2O

RM 280/2

WORK FIELDS

Average flow rates and average pressures.
TYPE OF IMPELLER

Type Curved Blades, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 0.75 kw, 2850 rpm, noise level 66 db,
Minimum flow rate 680 mc/h with 130 H2O
Maximum flow rate 1900 mc/h with head 69 H2O

RM 310/2

Features

WORK FIELDS

Average flows and average pressures.
TYPE OF IMPELLER

Type Curved Blades, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 1.5 kw, 2850 rpm, noise level 73 db,
Minimum flow rate 930 m3/h with 165 H2O
Maximum flow rate 2700 m3/h with head 88 H2O

RM 350/2

WORK FIELDS

Average flow rates and average pressures.
TYPE OF IMPELLER

Curved blade type, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 2.2 kw, 2800 rpm, noise level 78 db,
Minimum flow rate 1,330 m³/h with 210 H2O
Maximum flow rate 3,850 m³/h with head 113 H2O

Steel Exhaust Fans RL

serierh
1665757

Aspiration and transport of clean or slightly dusty air, for various applications in industrial plant engineering and air conditioning
Working range

Flow rates Medium - High and Low pressures.

Blade Type: Curved, backward (negative).

Applications

For the suction of clean and slightly dusty air, for applications in industrial plant engineering and in civil and industrial air conditioning. Standard construction executions

Standard fluid temperatures: -10° +60°C.

Type of construction: Fan in Fe360 sheet metal, impeller in Fe360 statically and dynamically balanced.

Operating data: Air conditions at suction T=20°C, 0m.a.s.l. and ρ=1.205 kg/m3

Noise Expressed in sound power L w A [dB(A)] measured in free field with ducted fan,
Orientations No.8 RD (clockwise rotation viewed from transmission side) and No.8 LG.

Fan in bolted adjustable version for sizes 250-630, fixed orientation for sizes 710-2000.


* Special constructions on request.

RL 280/2

RL 250/2

WORK FIELDS

High flow rates and medium-low pressures.
TYPE OF IMPELLER

Type Backward blades with cover.​
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 0.55 kw, 2850 rpm, noise level 63 db,
Minimum flow rate 1,080 mc/h with 87 H2o
Maximum flow rate 2,520 mc/h with head 35 H2o

WORK FIELDS

High flow rates and medium-low pressures.
TYPE OF IMPELLER

Type Backward blades with cover.​
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 1.1 kw, 2850 rpm, noise level 66 db,
Minimum flow rate 1,370 mc/h with 108 H2o
Maximum flow rate 3,600 mc/h with head 51 H2o

RL 310/2

RL 350/2

WORK FIELDS

High flow rates and medium-low pressures.
TYPE OF IMPELLER

Type Reverse blades with cover.​
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 2.2 kw, 2850 rpm, noise level 67 db,
Minimum flow rate 1,800 m³/h with 145 H2o
Maximum flow rate 5,400 m³/h with head 66 H2o

WORK FIELDS

High flow rates and medium-low pressures.
TYPE OF IMPELLER

Type Reverse blades with cover.​
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 3.00 kw, 2850 rpm, noise level 72 db,
Minimum flow rate 2,880 mc/h with 178 H2o
Maximum flow rate 7,200 mc/h with head 93 H2o

Accessories

for vacuum fans

demvtram
come-attaccare-paraspigoli-muro
flangia-per-filtri-depolveratori-800

Hopper

Siliconatura

Collar

  • code. HOPPER Ø200
  • code. HOPPER Ø250
  • code. HOPPER Ø300
  • code. HOPPER Ø350
  • code. HOPPER Ø400
  • Silicon sealant with high-temperature silicone
  • code. COLLAR Ø200
  • code. COLLAR Ø250
  • code. COLLAR Ø300
  • code. COLLAR Ø350
  • code. COLLAR Ø400