google-site-verification: google575aecfcdc9dadf3.html
TV Show
GreenBiz with Marco Columbro
aired on SKY
(full episode)
ETC
GROUP
TV
Feature Value Filter height 50 cm Extractor height 44 cm Total height 94 cm Filter depth 56 cm Width 62 cm Cold water supply 1/2" Condensate drain to sewer 1" Inlet diameter Ø 150 mm Outlet diameter Ø 140-150 mm Feature | Value |
---|---|
Filter height | 50 cm |
Extractor height | 44 cm |
Total height | 94 cm |
Filter depth | 56 cm |
Width | 62 cm |
Cold water supply | 1/2" |
Condensate drain to sewer | 1" |
Inlet diameter | Ø 150 mm |
Outlet diameter | Ø 140-150 mm |
Technical Data Sheet
User Manual
HIGH TEMPERATURE
ASPIRATORS
+300°
Code. INOX.4.EBR280
ETC Group S.r.l. Sole Shareholder
Industrial area Pirano, Tavullia
Str. Delle Campagne, 10
61010 Tavullia PU - ITALY
Tel.
+39 0721 1839937
+39 0541 955062
+39 0541 1646150
WhatsApp-web +39 373 7755779
E-Mail DEPARTMENTS
informazioni@etcgroupsrl.biz
commerciale@etcgroupsrl.biz
tecnico@etcgroupsrl.biz
contabilita@etcgroupsrl.biz
VAT and Tax Code: IT 04083110405
Reg. of companies of Pesaro N. REA - PS – 196574
- Scrubbers for Wood-fired Ovens
- Scrubbers for Electric Ovens
- Scrubbers for Charcoal Grills
- Stainless Steel Exhaust Fans
for Soot and Grease Eliminators
Centrifugal industrial fans are the fundamental component of air extraction systems for purification and filtration. These devices generate the necessary airflow to ensure the efficiency of aspiration systems across various industrial applications.
The UNI ISO 13349:2009 standard provides a precise technical definition of centrifugal industrial fans, specifying their characteristics, design criteria, and operational principles.
The effectiveness of ventilation is not solely determined by the direction of fan rotation but also by the correct configuration of the discharge outlet, the different construction types, and the motor positioning relative to the fan structure.
From an aerodynamic perspective, air enters the fan impeller in an axial direction and is discharged perpendicularly to the axis of rotation, ensuring efficient air movement and optimal management of flow rates and pressures within the extraction system.
Models
Line RM
STEEL EXHAUST FANS
Medium - high flow rates and low pressures.
STEEL FAN EXHAUSTERS
Medium flow rates and medium pressures.
Steel Fans Aspirators RM
Aspiration and transport of clean or slightly dusty air, for the most diverse applications in industrial plant engineering and air conditioning
Working range Medium flow rates and medium pressures. Type Curve Blades, reverse (negative).
Applications
For aspiration and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials. Standard construction executions Standard fluid temperatures -10÷ +60°C.
Type of construction: Fe360 sheet metal fan, Fe360 impeller statically and dynamically balanced.
Operating data: Air intake conditions T=20°C, 0m.a.s.l. and ρ=1.205 kg/m3.
Noise level: Expressed in sound power L w A [dB(A)] measured in free field with ducted fan.
Orientations: No.8 RD (clockwise rotation viewed from drive side) and No.8 LG.
Fan in bolted adjustable version for sizes 250-630, fixed orientation for sizes 710-2000.
Special constructions on request.
RM 250/2
Dimensions
WORK FIELDS
Average flows and average pressures.
TYPE OF IMPELLER
Curved Blade Type, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 0.37 kw, 2850 rpm, noise level 63 db,
Minimum flow rate 470 mc/h with 85 H2o
Maximum flow rate 1370 mc/h with head 44 H2O
RM 280/2
WORK FIELDS
Average flow rates and average pressures.
TYPE OF IMPELLER
Type Curved Blades, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 0.75 kw, 2850 rpm, noise level 66 db,
Minimum flow rate 680 mc/h with 130 H2O
Maximum flow rate 1900 mc/h with head 69 H2O
RM 310/2
Features
WORK FIELDS
Average flows and average pressures.
TYPE OF IMPELLER
Type Curved Blades, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 1.5 kw, 2850 rpm, noise level 73 db,
Minimum flow rate 930 m3/h with 165 H2O
Maximum flow rate 2700 m3/h with head 88 H2O
RM 350/2
WORK FIELDS
Average flow rates and average pressures.
TYPE OF IMPELLER
Curved blade type, reverse (negative).
APPLICATIONS
For the suction and transport of air from clean to very dusty, also containing sawdust, various chips, granular materials, excluding filamentous materials.
Electric power 2.2 kw, 2800 rpm, noise level 78 db,
Minimum flow rate 1,330 m³/h with 210 H2O
Maximum flow rate 3,850 m³/h with head 113 H2O
Steel Exhaust Fans RL
Aspiration and transport of clean or slightly dusty air, for various applications in industrial plant engineering and air conditioning
Working range
Flow rates Medium - High and Low pressures.
Blade Type: Curved, backward (negative).
Applications
For the suction of clean and slightly dusty air, for applications in industrial plant engineering and in civil and industrial air conditioning. Standard construction executions
Standard fluid temperatures: -10° +60°C.
Type of construction: Fan in Fe360 sheet metal, impeller in Fe360 statically and dynamically balanced.
Operating data: Air conditions at suction T=20°C, 0m.a.s.l. and ρ=1.205 kg/m3
Noise Expressed in sound power L w A [dB(A)] measured in free field with ducted fan,
Orientations No.8 RD (clockwise rotation viewed from transmission side) and No.8 LG.
Fan in bolted adjustable version for sizes 250-630, fixed orientation for sizes 710-2000.
* Special constructions on request.
RL 280/2
RL 250/2
WORK FIELDS
High flow rates and medium-low pressures.
TYPE OF IMPELLER
Type Backward blades with cover.
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 0.55 kw, 2850 rpm, noise level 63 db,
Minimum flow rate 1,080 mc/h with 87 H2o
Maximum flow rate 2,520 mc/h with head 35 H2o
WORK FIELDS
High flow rates and medium-low pressures.
TYPE OF IMPELLER
Type Backward blades with cover.
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 1.1 kw, 2850 rpm, noise level 66 db,
Minimum flow rate 1,370 mc/h with 108 H2o
Maximum flow rate 3,600 mc/h with head 51 H2o
RL 310/2
RL 350/2
WORK FIELDS
High flow rates and medium-low pressures.
TYPE OF IMPELLER
Type Reverse blades with cover.
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 2.2 kw, 2850 rpm, noise level 67 db,
Minimum flow rate 1,800 m³/h with 145 H2o
Maximum flow rate 5,400 m³/h with head 66 H2o
WORK FIELDS
High flow rates and medium-low pressures.
TYPE OF IMPELLER
Type Reverse blades with cover.
APPLICATIONS
For the suction and transport of air from clean to slightly dusty. Wide application in industrial plant engineering and air conditioning.
Electric power 3.00 kw, 2850 rpm, noise level 72 db,
Minimum flow rate 2,880 mc/h with 178 H2o
Maximum flow rate 7,200 mc/h with head 93 H2o
Accessories
for vacuum fans
Hopper
Siliconatura
Collar